Digital Inputs and Outputs CME 2 User Guide
66 Copley Controls
6.3: Synchronizing PWM Switching Frequency
In some situations, such as when sampling small analog signals, it is desirable to
synchronize the PWM switching frequency among multiple amplifiers. In these cases, one
amplifier serves as a master for one or more slave amplifiers. The PWM sync output of
the master sends a signal that is received as a PWM sync input by each slave.
6.4: Analog I/O
A typical Analog I/O screen is shown below. Options vary with amplifier.
6.4.1: Analog Motor Temperature Sensor
Enter a voltage limit in mV. Fault will occur when voltage is above limit. Actual voltage is
the sensor reading in mV.