CME 2 User Guide Amplifier Setup Procedure
Copley Controls 29
3.2: Setup Procedure
1
Prepare for setup
Understand this procedure’s Warnings and Notes (p. 28).
Verify that amplifier power is OFF.
Verify wiring and connections.
Make sure motor is securely fastened with no load connected.
Apply power to the amplifier.
For off-line amplifiers apply 24V only.
For DC amplifiers apply AUX HV only.
2
Start CME 2 and enter Basic Setup parameters
Double-click CME 2 icon on the Windows desktop to start CME 2.
If necessary, Connect to an Amplifier in CME 2 (p. 20) from the list in the Copley
Neighborhood tree.
If the Basic Setup screen does not appear, click the Basic Setup button.
Choose:
In most cases, click Change Settings to Change Basic Setup
Settings (p. 34).
Then proceed to Step 3 of this Setup Procedure,
Enter Motor/Feedback/Brake Stop parameters (p. 30).
OR
To load a .ccx file that was prepared for the amplifier/motor
combination, see Copy Amplifier Data (p. 177). Then proceed to
Step 13 of this Setup Procedure, Test with load attached (p. 32).
OR
To complete the setup for a ServoTube motor, click ServoTube
Setup and see ServoTube Setup (p. 39).