CME 2 User Guide Motor/Feedback
Copley Controls 47
SSI
In the counts per rev text field, enter the number of counts per revolution, (see data sheet).
In the Number of Encoder Bits text field enter the number of encoder bits, (see data sheet).
Choose Binary or Gray.
BiSS
In the Bits text field specify the number of bits used for single turn Resolution (see encoder
data sheet). In the Number of Revolutions text field specify the number of turns (see
encoder data sheet). Optionally, specify the number of alignment bits text field if required
else set to 0. Select code format BiSS B or BiSS C.
In the BiSS Advanced Settings window click any of the listed choices and
choose Ok.