Vue de la page 139
Using CME 2 Xenus XTL User Guide
132 Copley Controls Corp.
6.4.3: Control Panel Monitor Channels
The Control Panel Monitor channels can display real-time values on up to three separate
variables.
To set up a monitor display box, click in the list box and select a variable from the list.
Disabled disables the display. Other options represent the following amplifier values:
Actual Current Following Error Passive Load Position
Actual Motor Velocity Commanded Current Limited Position
Actual Motor Position Commanded Velocity Analog Command
Actual Load Velocity Commanded Position Bus Voltage
Actual Load Position Profile Velocity Amplifier Temperature
Velocity Error Profile Acceleration Motor Phase Angle
Mode: Displays the amplifier’s present operating mode. In camming it also displays the active cam
table number.