Parameter Dictionary Parameters
Dive temperature A/D Reading. Units: degrees C.
Peak Current Limit. Also known as Boost current on stepper drives. This value
cannot exceed the peak current rating of the drive. Units: 0.01 A.
Continuous Current Limit. Also known as Run Current on stepper drives. This value
should be less than the User Peak Current Limit. Units: 0.01 A.
Time at Peak Current Limit. Also known as Time at Boost Current on stepper drives.
Units: mS.
The current loop is driven by the programmed current value.
The current loop is driven by the analog reference
The current loop is driven by the PWM input.
The current loop is driven by the function generator.
The velocity loop is driven by the programmed velocity value.
The velocity loop is driven by the analog reference.
The velocity loop is driven by the PWM.
The velocity loop is driven by the function generator.
The position loop is driven by the trajectory generator.
The position loop is driven by the analog reference.
The position loop is driven by the digital input lines. (Pulse & direction, master encoder, etc.)
The position loop is driven by the function generator.
The position loop is driven by the cam tables.
The drive is controlled by the CANopen or EtherCAT interface
The microstepper is driven by the trajectory generator.
The microstepper is driven by the digital input lines.
The microstepper is driven by the function generator.
The microstepper is driven by the cam tables.